CyberPower ONL Rackmount UPS OLS10KERT5UM 10000VA

2.799,00 €

In stock · delivery across CyprusFree pickup in Limassol
Add to Cart
CyberPower ONL Rackmount UPS OLS10KERT5UM 10000VA
CyberPower ONL Rackmount UPS OLS10KERT5UM 10000VA
2.799,00 €

Free delivery on small items with orders over €50

Guaranteed Safe Checkout
CyberPower ONL Rackmount UPS OLS10KERT5UM 10000VA
CyberPower ONL Rackmount UPS OLS10KERT5UM 10000VA
2.799,00 €

Or contact us directly:

📞 25 102 760
📱 96 401 000

Specifications

Specifications82
Phase
Single Phase
Form Factor
Rackmount, Tower
UPS Topology
Online Double Conversion
Energy Saving Technology
ECO Mode Efficiency > 98%
Active PFC Compatibility
Yes
Parallel Expansion (Max. Units)
4 (Optional)  
Generator Compatibility
Yes
Nominal Input Voltage ( Vac )
230 ± 10%
Input Voltage Range ( Vac )
110 ~ 300
Input Frequency ( Hz )
50 ± 10, 60 ± 10
Input Frequency Detection
Auto-sensing
Rated Input Current ( A )
45.5
Input Power Factor
0.99
Input Connector Type
Hardwire Terminal Block  
Capacity (VA)
10000
Capacity (Watts)
10000
On Battery Waveform
Pure Sine Wave
On Battery Voltage(s) ( Vac )
208 ± 1 %, 220 ± 1 %, 230 ± 1 %, 240 ± 1 %
Output Voltage Setting
Configurable
On Battery Frequency ( Hz )
50 ± 0.5%, 60 ± 0.5%
Output Frequency Setting
Configurable
Power Factor
1
ECO Mode Voltage Tolerance
± 10 %
Overload Protection
Internal Current Limiting, Circuit Breaker, Fuse
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<1.5%
Harmonic Distortion (Non-linear Load)
THD<3%
Internal Bypass
Automatic Bypass, Manual Bypass
Maintenance Bypass
Yes
Outlet(s) - Total
9
Outlet Type
Hardwire Terminal Block x 1, IEC C13 x 4, IEC C19 x 4  
Typical Transfer Time ( ms )
0  
Runtime at Half Load ( min )
11.2
Runtime at Full Load ( min )
2.9
Typical Recharge Time ( Hours )
4
Maximum Charging Current ( A )
4
Start On Battery
Yes
Smart Battery Management (SBM)
Yes
User-replaceable
Yes - Qualified Personnel Only
Battery Type
Sealed Lead-acid
Replacement Battery Pack (RBP)
RBP0191
Replacement Battery Pack (RBP) Quantity ( pcs )
2
Battery Quantity (Each RBP) ( pcs )
10
Compatible Extended Battery Module (EBM)
BPS240V9ART3U
Extended Battery Module Auto-detection
Yes
Max. EBM Quantity ( pcs )
10  
Surge Suppression ( Joules )
1335
EMI/RFI Filtration
Yes  
LCD Panel
Yes
LCD Types
Color LCD
LCD Orientation
Rotatable LCD – Manual
Tiltable LCD Panel
15°
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting
LED Indicators
Power On
HID Compliant USB Port(s)
1
Serial Port
RS232
Dry Contact (with Relay)
Yes
Emergency Power Off (EPO) Port
Yes
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
Management Cable ( pcs )
Power Cord x4, USB Cable x1
Power Management Software
PowerPanel Business (Recommended)
SNMP/HTTP Remote Monitoring
Yes - RMCARD205 included
PowerPanel Cloud Service
Yes - 30 Days Free Trial with PowerPanel Personal/Business  
Enclosure Construction
Metal
Color
Black
Rackmount Rail
Yes
Rackmount Ears
Yes  
Dimensions (WxHxD) (mm.)
433 x 213.5 x 661
Weight (kg.)
80.4
Installed Rack Height ( U )
5  
Operating Temperature (°C)
0 ~ 40
Operating Relative Humidity (Non-condensing) ( % )
0 ~ 95
Operating Elevation ( meters )
≤1000, Load Derated 1% per 100m from 1000m and 2000m
Storage Temperature (°C)
-15 ~ 45
Storage Relative Humidity (Non-condensing) ( % )
0 ~ 95
Storage Elevation ( meters )
0-15,000 meters
Online Thermal Dissipation ( BTU/hr )
2047
Audible Noise at 1.0M from Surface of Unit ( dBA )
60  
Certifications
CE
RoHS
Yes  
Rack/Tower Convertible Configurations
Yes

The CyberPower OLS10KERT5UM is a high-efficiency UPS featuring online double-conversion topology, which provides seamless Pure Sine Wave power for mission-critical devices such as NAS, servers, DVRs/surveillance systems, transportation, infrastructure, and emergency systems. It’s typically integrated into the back office, server room, and data center environment.

With high output power factor, the UPS in a smaller footprint can provide more usable power and save rack space. The product allows multiple UPS units to be connected in parallel, achieving higher capacity and power redundancy. The pre-installed Maintenance Bypass PDU (MBP) offers quick and safe maintenance without power interruption. Moreover, the tiltable color LCD comes with an intuitive and graphical interface, allowing users to monitor and configure settings with ease. Besides, the battery charging current is adjustable via LCD setting to shorten charging time. It is also designed with relay-type dry contact port to support specific UPS event notifications for easy management.

  • Online (Double Conversion) UPS Topology
  • High Output Power Factor
  • Overload Protection
  • UPS Parallel Expansion (Optional)
  • Extended Battery Module (EBM)
  • Color LCD Panel
  • Emergency Power Off (EPO) Port
  • PowerPanel Management Software
  • Rack/Tower Convertible Configurations
  • ECO Mode
  • Pure Sine Wave Output
  • Zero Transfer Time
  • Maintenance Bypass Switch
  • Extended Battery Module Auto-detection
  • Tiltable LCD Panel
  • Relay-type Dry Contact
  • SNMP/HTTP Remote Management Capability